Journal Article
Print(0)
ISA transactions
ISA Trans.
/
42
2
171
179
0019-0578
Unknown(0)
In this paper the metrological behavior of two different insertion flowmeters (magnetic and turbine types) in large water pipes is described. A master-slave calibration was carried out in order to estimate the overall uncertainty of the tested meters. The experimental results show that (i) the magnetic insertion tested flowmeter performs the claimed accuracy (+/- 2%) within all the flow range (20:1); (ii) the insertion turbine tested meter, instead, reaches the claimed accuracy just in the upper zone of the flow range.
article
MEDLINE
Embase
Cascetta,F., Palombo,A., Scalabrini,G.
Cascetta, F., DETEC, University of Naples Federico II, Italy.
http://vp9py7xf3h.search.serialssolutions.com/?charset=utf-8&pmid=
2003